Chlamydia trachomatis, Neisseria Gonorrhea na Trichomonas vaginalis.

Nkọwa dị mkpirikpi:

Ezubere ngwa a maka nchọpụta in vitro qualitative chlamydia trachomatis (CT), Neisseria gonorrheae (NG)naTrichomonal vaginitis (TV) na nwoke urethral swab, nwanyi cervical swab, na nwanyi swab samples, na-enye aka na nchoputa na ọgwụgwọ nke ndị ọrịa nwere genitourinary tract ọrịa.


Nkọwa ngwaahịa

Mkpado ngwaahịa

Aha ngwaahịa

HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonorrhoeae na Trichomonas vaginalis Nucleic Acid Detection Kit (Fluorescence PCR)

Epidemiology

Chlamydia trachomatis (CT) bụ ụdị prokaryotic microorganism nke na-akpachapụ anya parasitic na sel eukaryotic.Chlamydia trachomatis na-ekewa n'ime AK serotypes dịka usoro serotype siri dị.Ọrịa urogenital tract na-ebutekarị site na trachoma biological variant DK serotypes, na ụmụ nwoke na-egosipụtakarị dị ka urethritis, nke nwere ike ịwepụ ya na-enweghị ọgwụgwọ, ma ọtụtụ n'ime ha na-aghọ nke na-adịghị ala ala, na-akawanye njọ mgbe ụfọdụ, a pụkwara ijikọta ya na epididymitis, proctitis, wdg.

Ọwa

FAM Chlamydia trachomatis
ROX Neisseria gonorrhea
CY5 Trichomonal vaginitis
VIC/HEX Njikwa ime

Nka nka

Nchekwa

-18 ℃

Ndụ nchekwa Ọnwa iri na abụọ
Ụdị ụdị Ọkpụkpụ cervical nwanyị,Ọkpụkpụ ikpu nwanyị,Nwoke urethra swab
Ct ≤38
CV <5%
LoD 400Mpempe akwụkwọ/ml
Nkọwapụta Ọ dịghị cross-reactivity na ndị ọzọ STD nje pathogens n'èzí nchọpụta nso nke ule kit, dị ka Treponema pallidum, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus ụdị 1, Herpes simplex virus ụdị 2, Candida albicans, wdg.
Ngwa ndị ọdabara Ngwa Biosystem 7500 ezigbo oge PCR

Ngwa Biosystem 7500 Ngwa PCR ngwa ngwa ozugbo

QuantStudio®Sistemụ PCR 5 ezigbo oge

Sistemụ PCR SLAN-96P ezigbo oge

LightCycler®Sistemụ PCR 480 ezigbo oge

Sistemụ nchọpụta PCR nke LineGene 9600 Plus

MA-6000 Real-Time Quantitative Thermal Cycler

BioRad CFX96 ezigbo oge PCR sistemụ

BioRad CFX Opus 96 PCR ezigbo oge

Usoro ọrụ

Nhọrọ 1.

Reagement mmịpụta akwadoro: Pipette 1mL nke ihe nlele a ga-anwale ka ọ bụrụ 1.5mL nke DNA centrifuge tube na-enweghị RNase, centrifuge na 12000rpm maka nkeji 3, tụfuo ihe dị elu wee dobe mmiri ozuzo.Tinye 200µL nke saline nkịtị ka ọ na-ebuli elu ka ọ kwụsịlata.Macro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (nke enwere ike iji Macro & Micro-Test Automatic Nucleic Acid Extractor). (HWTS-3006C, HWTS-3006B)) nke Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ekwesịrị ịme mmịpụta dịka ntuziaka maka ojiji.Olu nlele ewepụtara bụ 200µL, na olu elution akwadoro bụ 80µL.

Nhọrọ 2.

Reagent mmịpụta akwadoro: Mwepụta Nucleic Acid ma ọ bụ Ngwa Ọcha (YDP302).Ekwesịrị ịme mmịpụta ahụ nke ọma dịka ntuziaka maka ojiji.Olu elution akwadoro bụ 80µL.


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a ziga anyị ya