Ọrịa ịba ọcha n'anya E

Nkọwa dị mkpirikpi:

Ngwa a dabara adaba maka nchọpụta qualitative nke nje ịba ọcha n'anya E (HEV) nucleic acid na serum sample na stool samples in vitro.


Nkọwa ngwaahịa

Mkpado ngwaahịa

Aha ngwaahịa

HWTS-HP006 Hepatitis E Virus Nchọpụta Nchọpụta Acid (Fluorescence PCR)

Epidemiology

Ọrịa ịba ọcha n'anya E (HEV) bụ nje RNA na-ebute nsogbu ahụike zuru ụwa ọnụ.Ọ nwere nnukwu nnabata nnabata ma nwee akụrụngwa nke ịgafe ihe mgbochi interspecies.Ọ bụ otu n'ime ọrịa nje zoonotic kacha mkpa na-ebute oke mmerụ ahụ mmadụ na anụmanụ.A na-ebunye HEV tumadi site na mbufe fecal-oral, a pụkwara ibunye ya kwụ ọtọ site na embrayo ma ọ bụ ọbara.N'ime ha, n'okporo ụzọ nnyefe nke fecal-oral, mmiri na nri ndị na-emerụ emerụ na-agbasa ebe niile, ihe ize ndụ nke ibute ọrịa HEV na ụmụ mmadụ na anụmanụ dị elu[1-2].

Ọwa

FAM HEV nucleic acid
ROX

Njikwa ime

Nka nka

Nchekwa

≤-18℃

Ndụ nchekwa Ọnwa iri na abụọ
Ụdị ụdị Akpịrị swab
Tt ≤38
CV ≤5.0%
LoD 500 oyiri/μL
Nkọwapụta

Ọrịa ịba ọcha n'anya E (HEV) bụ nje RNA na-ebute nsogbu ahụike zuru ụwa ọnụ.Ọ nwere nnukwu nnabata nnabata ma nwee akụrụngwa nke ịgafe ihe mgbochi interspecies.Ọ bụ otu n'ime ọrịa nje zoonotic kacha mkpa na-ebute oke mmerụ ahụ mmadụ na anụmanụ.A na-ebunye HEV tumadi site na mbufe fecal-oral, a pụkwara ibunye ya kwụ ọtọ site na embrayo ma ọ bụ ọbara.N'ime ha, n'okporo ụzọ nnyefe nke fecal-oral, mmiri na nri ndị na-emerụ emerụ na-agbasa ebe niile, ihe ize ndụ nke ibute ọrịa HEV na ụmụ mmadụ na anụmanụ dị elu[1-2].

Ngwa ndị ọdabara Ngwa Biosystem 7500 ezigbo oge PCR

Ngwa Biosystems 7500 Ngwa PCR ngwa ngwa ozugbo

Sistemụ PCR ezigbo oge QuantStudio5

SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.)

Sistemụ PCR Real-Time LightCycler®480

Sistemụ nchọpụta PCR nke LineGene 9600 Plus (FQD-96A, teknụzụ Hangzhou Bioer)

MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.)

BioRad CFX96 ezigbo oge PCR sistemụ

BioRad CFX Opus 96 PCR ezigbo oge

Usoro ọrụ

Nhọrọ 1

Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) na Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B).Ekwesịrị ịwepụta ya dịka ntuziaka ahụ si dị.Olu elution akwadoro bụ 80µL.

Nhọrọ 2

TIANAmp Virus DNA/RNA Kit (YDP315-R) nke Tiangen Biotech (Beijing) Co., Ltd rụpụtara. Ekwesịrị ịwepụta ya nke ọma dịka ntuziaka siri dị.Ihe nlele nke ewepụtara bụ 140 μl.Olu elution akwadoro bụ 60µL.v


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a ziga anyị ya