Ngwa Nchọpụta STI Multiplex 7

Nkọwa Dị Mkpirikpi:

Koodu Ngwaahịa

HWTS-UR012

Ojiji Ezubere

E bu n'obi ka e jiri ngwa a chọpụta ọrịa ndị na-efe efe n'ime eriri afọ, gụnyere Neisseria gonorrhoeae (NG), Chlamydia trachomatis (CT), Ureaplasma urealyticum (UU), Herpes Simplex Virus Type 1 (HSV1), Herpes Simplex Virus Type 2 (HSV2), Mycoplasma hominis (Mh), Mycoplasma genitalium (Mg) n'ime mmamịrị nwoke na ihe nlele nke ihe ndị na-esi n'ime akụkụ ahụ nwanyị pụta.


Nkọwa Ngwaahịa

Akara Ngwaahịa

Aha Ngwaahịa

Ngwa Nchọpụta STI Multiplex

Ọmụmụ ihe gbasara ọrịa na-efe efe

Ọrịa ndị a na-ebute site na mmekọahụ (STI) ka bụ otu n'ime ihe ndị na-eyi nchekwa ahụike ọha na eze n'ụwa niile egwu, nke nwere ike ibute enweghị ike ịmụ nwa, ịmụ nwa tupu oge eruo, etuto ahụ, na ọtụtụ nsogbu dị njọ. E nwere ọtụtụ ụdị nje STI, gụnyere nje bacteria, nje virus, chlamydia, mycoplasma, na spirochetes. NG, CT, UU, HSV 1, HSV 2, Mh, Mg bụ ihe a na-ahụkarị.

Usoro Nkà na ụzụ

Nchekwa ≤ -18℃
Ndụ nchekwa Ọnwa iri na abụọ
Ụdị ihe atụ Mmiri urethral, ​​ihe ndị na-eme ka ọkpụkpụ dị n'ime afọ pụta
CV <5.0%
LoD Oke Nchọpụta (LoD): LoD nke ngwa maka ịchọpụta CT, NG, UU, HSV1, HSV2 na Mg bụ 400Ndepụta/mL; LoD nke ngwa maka ịchọpụta Mh bụ 1000Ndepụta/mL.
Nkọwapụta Enweghị mmeghachi omume cross-reactions na nje ndị yiri STI.
Ngwa Ndị Dị Mkpa

Sistemụ PCR Oge-N'oge nke Biosystems 7500, Sistemụ PCR Oge-N'oge nke Biosystems 7500 Ngwa ngwa, Sistemụ PCR Oge-N'oge nke QuantStudio®5, Sistemụ PCR Oge-N'oge nke SLAN® -96P, Sistemụ PCR Oge-N'oge nke LightCycler® 480, Sistemụ Nchọpụta Oge-N'oge nke LineGene 9600 Plus (FQD-96A, teknụzụ Hangzhou Bioer), MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), Sistemụ PCR Oge-N'oge BioRad CFX96, Sistemụ PCR Oge-N'oge BioRad CFX Opus 96 na wdg.

Ọwa

Nchekwa Mmeghachi Omume Ebumnuche Onye nta akụkọ Onye na-egbu ọkụ
Nchekwa Mmeghachi Omume STI 1 CT FAM ọ dịghị
UU VIC (HEX) ọ dịghị
Mh ROX ọ dịghị
HSV1 CY5 ọ dịghị
Nchekwa Mmeghachi Omume STI 2 NG FAM ọ dịghị
HSV2 VIC (HEX) ọ dịghị
Mg ROX ọ dịghị
IC CY5 ọ dịghị

Usoro Ọrụ

670e945511776ae647729effe7ec6fa

Ihe ndị na-eme reagents chọrọ mana enyeghị ha

Ngwa Mwepụta Ihe Nlereanya Maka Nlereanya Macro na Micro (HWTS-3005-8); Ngwa Nlereanya Maka Nlereanya Macro na Micro-Nlereanya General DNA/RNA (HWTS-3017) (nke enwere ike iji ya na Macro & Micro-Nlereanya Akpaka Nucleic Acid Extractor (HWTS-EQ011)) nke Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Ekwesịrị ime mwepụta ahụ dịka IFU si dị.

A chọrọ ihe oriri mana enyeghị ha:1.5mL nke tube centrifuge DNase/RNase na-enweghị, Tips na-enweghị DNase/RNase, ihe ntinye desktọọpụ, igwekota oscillation desktọọpụ.


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a zitere anyị ya