Ọrịa ndị a na-ebute site na mmekọahụ (STIs) ka bụ otu n'ime ihe ndị kacha eyi ọha mmadụ egwunchekwa ahụike, ebe ọ bụ na ha nwere ike ibute enweghị ike ịmụ nwa, ịmụ nwa tupu oge eruo, ọrịa tumor, na ihe ndị ọzọ dị iche ichensogbu siri ike. Ọrịa nje nke STI dị iche iche, gụnyere nje bacteria, nje virus,Chlamydia, Mycoplasma, na spirochetes. Ụdị ndị a na-ahụkarị gụnyere Chlamydiatrachomatis, Ureaplasma urealyticum, Ureaplasma parvum, mycoplasma hominis,ụdị nje herpes simplex type 1 (HSV-1), Neisseria gonorrhoeae, ụdị nje herpes simplex2 (HSV-2), Mycoplasma genitalium, na Trichomonal vaginitis.
Usoro Nkà na ụzụ
| Nchekwa | ≤ -18℃ |
| Ndụ nchekwa | Ọnwa iri na abụọ |
| Ụdị ihe atụ | Mmamịrị, swab nke nwoke, swab nke nwanyị, swab nke nwanyị |
| CV | <5.0% |
| LoD | Oke Nchọpụta (LoD): LoD nke ngwa maka ịchọpụta CT, NG, UU, UP, HSV1, HSV2, Mg, na TV bụ 400Copies/mL; LoD nke ngwa maka ịchọpụta Mh bụ 1000Copies/mL. |
| Nkọwapụta | Enweghị mmeghachi omume cross-reactions na nje ndị yiri STI. |
| Ngwa Ndị Dị Mkpa | Ụdị m: Sistemụ PCR Oge-N'oge Ejiri Eme Ihe nke Biosystems 7500, Sistemụ PCR Oge-N'oge Ngwa Ngwa nke Biosystems 7500, Sistemụ PCR Oge-N'oge Ngwa Ngwa nke QuantStudio®5, Sistemụ PCR Oge-N'oge Ngwa Ngwa nke SLAN-96P (Hongshi Medical Technology Co., Ltd.), Sistemụ PCR Oge-N'oge Ngwa Ngwa nke LightCycler®480, Sistemụ Nchọpụta Oge-N'oge Ngwa Ngwa nke LineGene 9600 Plus (FQD-96A, teknụzụ Hangzhou Bioer) na MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), Ltd. Ụdị nke Abụọ: Eudemon TM AIO800 (HWTS-AIO800) nke Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Ọwa
Usoro ọrụ:
Ụdị I:
Ụdị nke Abụọ:
Ihe ndị na-eme ka ihe na-eme ka ihe na-eme ka ihe dị n'ime mmiri chọrọ mana enyeghị ha:
Ụdị m:
Ngwa Ngwuputa DNA/RNA nke Macro na Micro-Nnwale General (HWTS-3019) (nke enwere ike iji ya na Macro na Micro-Nnwale Automatic Nucleic Acid Extractor (HWTS-3006B),HWTS-3006C)) site na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., Macro &Kọlụm DNA/RNA nke nje bacteria Micro-Ule (HWTS-3022), Ngwọta Nchekwa Ihe Nlereanya(HWTS-3015) nke Jiangsu Macro & Micro-Test Med-Tech Co., Ltd..
Ụdị nke Abụọ:
Ngwa DNA/RNA nke nje Macro na Micro-Nnwale (HWTS-3019-8), ihe nleleNgwọta Nchekwa (HWTS-3015) nke Jiangsu Macro & Micro-Test Med-Tech Co.,Ltd.A chọrọ ihe oriri mana enyeghị ha:1.5mL nke ọkpọkọ centrifuge DNase/RNase na-enweghị,Ntuziaka na-enweghị DNase/RNase, centrifuge desktọpụ, igwekota oscillation desktọpụ.