Trichomonas vaginalis nucleic acid

Nkọwa dị mkpirikpi:

A na-eji ngwa a maka nchọpụta qualitative nke Trichomonas vaginalis nucleic acid na ihe nleba anya nzuzo urogenital mmadụ.


Nkọwa ngwaahịa

Mkpado ngwaahịa

Aha ngwaahịa

HWTS-UR011A-Trichomonas Vaginalis Ngwa nchọpụta Nucleic Acid (Mmụba Isothermal)

Epidemiology

Trichomonas vaginalis (TV) bụ parasitic flagellate na ikpu mmadụ na urinary tract, nke na-ebutekarị trichomonas vaginitis na urethritis, na ọ bụkwa ọrịa na-efe efe na-ebute site ná mmekọahụ.Trichomonas vaginalis nwere ike ime mgbanwe na gburugburu mpụga, igwe mmadụ na-adịkarị mfe.Enwere ihe dị ka nde mmadụ 180 bu ọrịa n'ụwa niile, ọnụ ọgụgụ ndị butere ọrịa a kacha elu n'etiti ụmụ nwanyị dị afọ 20 ruo 40. Ọrịa Trichomonas vaginalis nwere ike ime ka nje virus na-egbochi mmadụ (HIV), papillomavirus mmadụ (HPV), wdg. Nnyocha ọnụ ọgụgụ dị adị na-egosi na Ọrịa Trichomonas vaginalis nwere njikọ chiri anya na afọ ime ọjọọ, cervicitis, infertility, wdg, na-emetụtakwa ọnọdụ na prognosis nke traktị na-adịghị mma dị ka ọrịa kansa cervical, prostate cancer, wdg. Nchọpụta ziri ezi nke ọrịa Trichomonas vaginalis bụ njikọ dị mkpa. na mgbochi na ọgwụgwọ ọrịa ahụ, ọ dịkwa oke mkpa iji gbochie mgbasa nke ọrịa ahụ.

Ọwa

FAM TV nucleic acid
ROX

Njikwa ime

Nka nka

Nchekwa

Mmiri: ≤-18℃

Ndụ nchekwa Ọnwa 9
Ụdị ụdị secretions urethra, ihe nzuzo nke ikpu
Tt <30
CV ≤10.0%
LoD 3 mbipụta/µL
Nkọwapụta

Ọ dịghị cross-reactivity na ndị ọzọ urogenital tract samples, dị ka Candida albicans, Chlamydia trachomatis, Ureaplasma urealyticum, Neisseria gonorrhoeae, Group B streptococcus, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex nje, Human papillomavirus, Garalischelomavirus, Garalischelomavirus, Garalischelomavirus, Garalischelomavirus, Garalischelomavirus, Garalischelomavirus. Human Genomic DNA, wdg.

Ngwa ndị ọdabara

Sistemụ nchọpụta Isothermal Fluorescence dị mfe Amp (HWTS 1600)

Ngwa Biosystem 7500 ezigbo oge PCR

Ngwa Biosystem 7500 Ngwa PCR ngwa ngwa ozugbo

Sistemụ PCR ezigbo oge QuantStudio5

Sistemụ PCR SLAN-96P ezigbo oge

Sistemụ PCR Real-Time LightCycler®480

Sistemụ nchọpụta PCR nke LineGene 9600 Plus

MA-6000 Real-Time Quantitative Thermal Cycler

BioRad CFX96 ezigbo oge PCR sistemụ

BioRad CFX Opus 96 PCR ezigbo oge

Usoro ọrụ

Nhọrọ 1.

Na-atụ aro mmịpụta reagent: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8) nke Jiangsu Macro & Micro-Test Med-Tech Co., Ltd mepụtara.

Nhọrọ 2.

Na-atụ aro mmịpụta reagent: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3001, HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) na Macro & Micro-Test akpaka Nucleic Acid Extractor (HWTS-) 3006) nke Jiangsu Macro & Micro-Test Med-Tech Co., Ltd mepụtara.


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a ziga anyị ya