Enterovirus 71 (EV71)

Nkọwa dị mkpirikpi:

Ezubere ngwa a maka nchọpụta qualitative in vitro nke enterovirus 71 (EV71) nucleic acid na oropharyngeal swabs na ihe nlele mmiri herpes nke ndị ọrịa nwere ọrịa ọnụ ụkwụ.


Nkọwa ngwaahịa

Mkpado ngwaahịa

Aha ngwaahịa

HWTS-EV003-Enterovirus 71 (EV71) Ngwa nchọpụta Nucleic Acid (Fluorescence PCR)

Epidemiology

Ọrịa ọnụ ụkwụ aka bụ ọrịa na-efe efe nke enteroviruses (EV) kpatara.Ugbu a, a chọtara ụdị serotypes nke enteroviruses dị 108, nke kewara ụzọ anọ: A, B, C na D. N'ime ha, enterovirus EV71 na CoxA16 bụ ndị na-akpata ọrịa.Ọrịa a na-emekarị n'ime ụmụaka na-erubeghị afọ 5, ọ pụkwara ịkpata herpes na aka, ụkwụ, ọnụ na akụkụ ndị ọzọ.Ọnụ ọgụgụ dị nta nke ụmụaka ga-enwe nsogbu dị ka myocarditis, pulmonary edema, na aseptic meningoencephalitis.

Ọwa

FAM EV71
ROX

Njikwa ime

Nka nka

Nchekwa

≤-18℃

Ndụ nchekwa Ọnwa 9
Ụdị ụdị Oropharyngeal swab,Herpes mmiri
Ct ≤35
CV <5.0%
LoD 500 oyiri/ml
Ngwa ndị ọdabara Ngwa Biosystem 7500 ezigbo oge PCR Sistemu

Ngwa Biosystem 7500 Ngwa PCR ngwa ngwa ozugbo

QuantStudio®Sistemụ PCR 5 ezigbo oge

Sistemụ PCR SLAN-96P ezigbo oge

LightCycler®Sistemụ PCR 480 ezigbo oge

Sistemụ nchọpụta PCR nke LineGene 9600 Plus

MA-6000 Real-Time Quantitative Thermal Cycler

BioRad CFX96 ezigbo oge PCR sistemụ

BioRad CFX Opus 96 PCR ezigbo oge

Usoro ọrụ

Nhọrọ 1.
Na-atụ aro mmịpụta reagent: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8), na mmịpụta ga-eduzi dị ka ntuziaka maka ojiji.Ihe nlele ndị a amịpụtara bụ swabs oropharyngeal ma ọ bụ ihe nlele mmiri herpes sitere na ndị ọrịa anakọtara na saịtị.Tinye swabs anakọtara n'ime Macro & Micro-Test Sample Release Reagent (HWTS-3005-8) ozugbo, vortex na gwakọta nke ọma, tinye ya na ụlọ okpomọkụ maka nkeji 5, wepụ ha wee tụgharịa ka ọ gwakọta nke ọma, iji nweta RNA. nke ọ bụla sample.

Nhọrọ 2.
Na-atụ aro mmịpụta reagent: Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (nke a pụrụ iji na Macro & Micro-Test). Akpaaka Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) nke Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., na mmịpụta kwesịrị iduzi dị ka ntuziaka maka ojiji.Olu nlele ewepụtara bụ 200µL, na olu elution akwadoro bụ 80µL.

Nhọrọ3.
Reagenti mmịpụta akwadoro: QIAamp Viral RNA Mini Kit (52904) nke QIAGEN ma ọ bụ TIANAmp Nje Virus DNA/RNA Kit (YDP315-R), na mmịpụta kwesịrị ka eme ya n'ụzọ siri ike dabere na ntuziaka maka ojiji.Olu ihe nlele ewepụtara bụ 140μL, na olu elution akwadoro bụ 60µL.


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a ziga anyị ya