Klebsiella Pneumoniae, Acinetobacter Baumannii na Pseudomonas Aeruginosa na Mkpụrụ ndụ ihe nketa na-eguzogide ọgwụ (KPC, NDM, OXA48 na IMP) Multiplex
Aha ngwaahịa
HWTS-RT109 Klebsiella Pneumoniae, Acinetobacter Baumannii na Pseudomonas Aeruginosa na Mkpụrụ ndụ ihe nketa na-eguzogide ọgwụ (KPC, NDM, OXA48 na IMP) Ngwa Nchọpụta Multiplex (Fluorescence PCR)
Asambodo
CE
Ọmụmụ ihe gbasara ọrịa na-efe efe
Klebsiella pneumoniae bụ nje bacteria na-akpata ọrịa n'oge na-adịghị anya, ọ bụkwa otu n'ime nje bacteria dị mkpa na-akpata ọrịa n'oge na-adịghị anya. Mgbe ahụ mmadụ na-ebelata ike iguzogide ya, nje bacteria na-abanye n'ime ngụgụ site na akụkụ iku ume, na-ebute ọrịa n'ọtụtụ akụkụ ahụ, ojiji ọgwụ nje n'oge bụ isi ihe dị mkpa iji gwọọ [1]. Ebe a na-ahụkarị ọrịa Acinetobacter baumannii bụ ngụgụ, nke bụ nje dị mkpa maka pneumonia ụlọ ọgwụ (HAP), ọkachasị pneumonia metụtara Ventilator (VAP). Ọ na-esokarị ọrịa nje bacteria na fungal ndị ọzọ, yana njirimara nke oke ọrịa na oke ọnwụ. Pseudomonas aeruginosa bụ nje bacteria na-anaghị amịpụta gram-negative kachasị na omume ụlọ ọgwụ, ọ bụkwa nje bacteria dị mkpa maka ọrịa ndị ụlọ ọgwụ na-enweta, yana njirimara nke mfe ịmịpụta, mgbanwe dị mfe na iguzogide ọtụtụ ọgwụ.
Usoro Nkà na ụzụ
| Nchekwa | ≤-18℃ |
| Ndụ nchekwa | Ọnwa iri na abụọ |
| Ụdị ihe atụ | Sputum |
| Ct | ≤36 |
| CV | ≤5.0% |
| LoD | 1000 mbipụta/mL |
| Nkọwapụta | a) Nnwale mmeghachi omume nke cross-reactivity na-egosi na ngwa a enweghị mmeghachi omume cross-reactivity na nje ndị ọzọ na-efe efe, dịka Streptococcus pneumoniae, Neisseria meningitidis, Staphylococcus aureus, Klebsiella oxytoca, Haemophilus influenzae, Acinetobacter jelly, Acinetobacter hemolytica, Legionella pneumophila, Escherichia coli, Pseudomonas fluorescens, Candida albicans, Chlamydia pneumoniae, Respiratory Adenovirus, Enterococcus na sputum samples na-enweghị ihe mgbaru ọsọ, wdg. b) Ike mgbochi nnyonye anya: Họrọ mucin, minocycline, gentamicin, clindamycin, imipenem, cefoperazone, meropenem, ciprofloxacin hydrochloride, levofloxacin, clavulanic acid, na roxithromycin, wdg. maka ule nnyonye anya, nsonaazụ ya na-egosi na ihe nnyonye anya ndị a kpọtụrụ aha n'elu anaghị egbochi nchọpụta nke Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa na mkpụrụ ndụ ihe nketa carbapenem KPC, NDM, OXA48 na IMP. |
| Ngwa Ndị Dị Mkpa | Sistemụ PCR Oge-N'ezie nke Biosystems 7500, Sistemụ PCR Ngwa-ngwa Ngwa Ngwa 7500 nke Ejiri Mee Ihe, QuantStudio®Sistemụ PCR 5 n'oge a, LightCycler®Sistemụ PCR oge 480, Sistemụ Nchọpụta PCR LineGene 9600 Plus nke oge a (FQD-96A, teknụzụ Bioer), MA-6000 Ngwa Okpomọkụ Oge A Na-ahụ Anya (Suzhou Molarray Co., Ltd.), Sistemụ PCR oge-oge BioRad CFX96, Sistemụ PCR BioRad CFX Opus 96 n'oge dị adị. |
Usoro Ọrụ
A na-atụ aro ka e wepụta ihe nlele ahụ na Macro & Micro-Test General DNA/RNA Kit (HWTS-3019) (nke enwere ike iji Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, (HWTS-3006B) site na Jiangsu Macro & Micro-Test Med-Tech Co., Ltd., ma mee usoro ndị na-esote dịka IFU nke Kit si dị.