Influenza A Nje Virus Universal/H1/H3

Nkọwa dị mkpirikpi:

A na-eji ngwa a maka nchọpụta qualitative nke influenza A nje eluigwe na ala, ụdị H1 na H3 ụdị nucleic acid na mmadụ nasopharyngeal swab samples.


Nkọwa ngwaahịa

Mkpado ngwaahịa

Aha ngwaahịa

HWTS-RT012 Influenza A Virus Universal/H1/H3 Nucleic Acid Multiplex Detection Kit (Fluorescence PCR)

Epidemiology

Nje virus influenza bụ ihe nnọchianya nke Orthomyxoviridae. Ọ bụ ọrịa nje na-eyi ahụ́ ike mmadụ egwu nke ukwuu. Ọ nwere ike ibunye onye ọbịa ahụ nke ukwuu. Ọrịa na-efe efe nke oge a na-emetụta ihe dị ka nde mmadụ 600 n'ụwa nile ma na-akpata ọnwụ 250,000 ~ 500,000, nke nje influenza A bụ isi ihe na-ebute ọrịa na ọnwụ. Influenza A bụ nje RNA na-adịghị mma nwere otu eriri. Dị ka elu hemagglutinin (HA) na neuraminidase (NA), HA nwere ike kewaa n'ime 16 subtypes, NA Kewara n'ime 9 subtypes. N'ime nje virus influenza A, ụdị subtypes nke nje influenza nwere ike ibunye mmadụ ozugbo bụ: A H1N1, H3N2, H5N1, H7N1, H7N2, H7N3, H7N7, H7N9, H9N2 na H10N8. N'ime ha, H1 na H3 subtypes bụ nnukwu ọrịa na-efe efe, ma bụrụ ndị kwesịrị nlebara anya karịsịa.

Ọwa

FAM influenza A eluigwe na ala ụdị nje nucleic acid
VIC/HEX influenza A H1 ụdị nje nucleic acid
ROX influenza A H3 ụdị nje nucleic acid
CY5 njikwa ime

Nka nka

Nchekwa

≤-18℃

Ndụ nchekwa Ọnwa 9
Ụdị ụdị nasopharyngeal swab
Ct ≤38
CV ≤5.0%
LoD 500 oyiri/μL
Nkọwapụta

Ọ dịghị cross-reactivity na ndị ọzọ akụkụ okuku ume samples dị ka Influenza A, Influenza B, Legionella pneumophila, Rickettsia Q fever, Chlamydia pneumoniae, Adenovirus, Respiratory Syncytial Virus, Parainfluenza 1, 2, 3, Coxsackie virus, Echo virus, Metapneu/B1. nje syncytial A/B, Coronavirus 229E/NL63/HKU1/OC43, Rhinovirus A/B/C, Boca virus 1/2/3/4, Chlamydia trachomatis, adenovirus, wdg na mmadụ genomic DNA.

Ngwa ndị ọdabara Ngwa Biosystem 7500 ezigbo oge PCR

Ngwa Biosystem 7500 Ngwa PCR ngwa ngwa ozugbo

Sistemụ PCR Real-Time QuantStudio®5

SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.)

Sistemụ PCR Real-Time LightCycler®480

Sistemụ nchọpụta PCR nke LineGene 9600 Plus (FQD-96A, teknụzụ Hangzhou Bioer)

MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.)

BioRad CFX96 ezigbo oge PCR sistemụ

BioRad CFX Opus 96 PCR ezigbo oge

Usoro ọrụ

Nucleic Acid mmịpụta ma ọ bụ reagent dị ọcha (YDP315-R) nke Tiangen Biotech (Beijing) Co., Ltd. Ekwesịrị ịme mmịpụta ahụ nke ọma dịka ntuziaka maka ojiji. Ihe nlele nke ewepụtara bụ 140μL, na olu elution akwadoro bụ 60μL.

Nhọrọ 2.

Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) na Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B). Ekwesịrị ịme mmịpụta ahụ nke ọma dịka ntuziaka maka ojiji. Ihe nlele nke ewepụtara bụ 200μL, na olu elution akwadoro bụ 80μL.


  • Nke gara aga:
  • Osote:

  • Dee ozi gị ebe a ziga anyị ya